8607 WESTWOOD CENTER DRIVE

Existing eye bolt not up to standards

 

Summit Anchor Co. pad eye

 

Location:
8607 Westwood Center Drive
Vienna, VA

Date:
April 2009

Client:
America's Capital Partner's Mid-Atlantic, LLC.

Project Type:
Retrofit – Occupied

Building Features:
EPDM (membrane systems)

Structural Attachment Considerations:
Chemical fasteners for concrete
Through bolted fasteners for wrapping steel framing
Through bolted fasteners for concrete
Welded for steel framing

Products Supplied, Installed, and Tested:
SM-81-PLT-F1 Curb anchors
SM-TRA-ADH-7 Chemical anchor fasteners
SM-81-4-12 Wall anchors
SM-PLT-412-58 Bottom plates
SM-TRA Threaded rod assemblies
SM-84-4 Wall anchors
SM-4-4-13.5 Roof anchors
SM-DVT-BSE-S4 Stanchion davit bases
SM-DVT-PA Davit portable adapters
SM-DVT-SKT Davit sockets
SM-DVT-ARM Davit arms
SM-HLL Horizontal cable systems

Objective:
Design and install a suspended maintenance system for this existing building, which previously did not meet OSHA and ANSI/IWCA I-14.1 requirements for suspended maintenance workers. Most products were welded to steel beams. Because welding sparks were a concern, fire retardant was applied around the roof deck opening to minimize sparks. Summit Anchor Co. tested and certified all anchors after installation. A level was used to determine if any permanent deflection occurred during the anchor test.